Upload Sensor Calibrations¶
This guide shows how to upload sensor calibration records with optional PDF datasheet attachments.
Prerequisites¶
- Sensors already uploaded (see Upload Sensors)
- A signal-sensor map linking signal names to sensor lookup parameters
- A signal-calibration map with dates and filenames
- A directory of calibration PDF files
Steps¶
1. Set up the uploader¶
from owi.metadatabase.shm import ShmAPI, ShmSensorUploader
api = ShmAPI(
api_root="https://owimetadatabase.azurewebsites.net/api/v1",
token="your-api-token",
)
uploader = ShmSensorUploader(shm_api=api)
2. Prepare the mapping data¶
Signal-sensor map — maps each signal to its sensor lookup parameters:
signal_sensor_map = {
"WTG01": {
"NRT_WTG_TP_ACC_AX": {
"sensor_type_id": {"name": "393B04"},
"serial_number": "SN001",
}
}
}
Signal-calibration map — maps each signal to calibration metadata:
signal_calibration_map = {
"WTG01": {
"NRT_WTG_TP_ACC_AX": {
"date": "2023-01-15",
"filename": "SN001_calibration.pdf",
}
}
}
3. Upload¶
results = uploader.upload_sensor_calibrations(
signal_sensor_map_data=signal_sensor_map,
signal_calibration_map_data=signal_calibration_map,
path_to_datasheets="data/sensors/datasheets/",
)
The uploader resolves sensor IDs from the signal-sensor map (including nested sensor type lookups), then creates a calibration for each signal with the matching PDF attached when found on disk.